After Through evaluation Prefab structure switched over to "TRACK & PANEL" system and standardized construction procedures.
This System was tested at Structural Engineering Laboratory, Chennai.
It was proved that Double Skin Wall made of 2 Nos. Bison Panels can take a vertical Load of 1.25 MT per R. Ft.
We have also conducted tests for:
| Density | 1250 kg/m3 average |
| Modulus of Elasticity | (bending) 3000 N/mm square 0.4 N/mm square |
| Transverse tensile strength | (Internal bond perpendicular to surface) |
| Compressive strength | 15 N/mm square (Perpendicular to surface) |
| Nail holding Power | 205 Kgs (perpendicular to surface) |
| Screw holding power | 312 kgs (perpendicular to surface) |
| Moisture content | 9 % + 3 on delivery |
| Surface alkalinity pH between | 11 and 13. |
| Thermal Conductivity coefficient | 0.22 w/mk |
| Dimensions | 2440 x 1220 mm (8 x 4) 3050 x 1220 mm (10 x 4) |
| Thickness | 6, 8, 10, 12, 16, 20, 25, 30, 40 mm. |
| Thickness | 6-10 mm + 0.7 mm 12-16 mm + 1.0 mm 20-40 mm + 1.5 mm |
| Length | + 5mm |
| Squareness | + 2.5 mm on the width of the panel |